10. Fault Commands

10-6

August 2002

4200-A2-GB20-00

Response Format

If, in less than 2 seconds, a normal or error response cannot be sent, the following
acknowledgment response will be sent:

IP c

After the above response, a new command input may be generated.

Normal Response:

sid yy-mm-dd hh:mm:ss
M c COMPLD
/* RTRV-ALM-ALL:[tid]:aid_all:[ctag]::[ntfncde]
,,[srveff] */
"aid_adsl,[aid_type]:ntfncde,cond_adsl,serveff,,,[locn],
[dirn],:[cond_descr]"
;

Error Response:

sid yy-mm-dd hh:mm:ss
M c DENY

/* RTRV-ALM-ALL:[tid]:aid_all:[ctag]::[ntfncde],,
[srveff] */
errcde

;

Table 10-4.

RTRV-ALM-ALL Response Parameters (1 of 2)

Parameter Explanation

tid Target

NE

identification

yy-mm-dd

Year, month, and day

hh:mm:ss

Hour, minute, and second

M

Message generated in response to an input command

c

If provided, ctag; otherwise 0

COMPLD Completed

DENY

Input command is denied

/* */

Enclosed are human readable comments – unspecified format

errcde Error

code

(see

Appendix A,

Error Codes

)

aid

Access identifier associated with the alarm. Valid values are:

SHELF-rack-shelf

LTA-rack-shelf-slot

ADSL-rack-shelf-slot-circuit

NTT1-circuit

[aid_type]

The type of Access Identifier.