beautypg.com

Rosemount 5300 series – Emerson Process Management ROSEMOUNT 5300 User Manual

Page 96

background image

Reference Manual

00809-0100-4530, Rev BA

July 2009

Rosemount 5300 Series

5-24

Rosemount Radar Master (RRM) includes tools to estimate the dielectric
constant of the current product:

The Dielectric Chart lists the dielectric constant of a large number of
products. The Dielectric Chart can be opened with one of the following
methods:
- Choose the View>Dielectric Constant Chart menu option
- Click the Dielectric Chart button

in the Configuration Wizard -

Environment window
- Choose the Setup>Tank menu option and click the Dielectric Chart
button

in the Tank/Environment window

The Dielectric Calculator

lets you calculate the dielectric constant

of the Upper Product based on the following input:
- actual upper product thickness,
- the dielectric constant value stored in the transmitter, and
- the upper product thickness presented by the transmitter.

The Dielectric Calculator is available via the Dielectric Calculator
button

in the Configuration Wizard - Environment window or the

Tank/Environment window.