Display / Configuration (continued)
F
OUNDATION
Fieldbus
Class (Basic or Link
Master)
Link Master (LAS).
F
OUNDATION
Fieldbus
Block Execution Time
AI-block: 30 ms. PID-block: 40 ms.
ARTH-, ISEL-, OSPL-block: 65 ms. CHAR-block: 75 ms.
F
OUNDATION
Fieldbus
Instantiation
No.
Conforming F
OUNDATION
Fieldbus
ITK 5.0.
F
OUNDATION
Fieldbus
PlantWeb
®
Alert Support
Yes.
Damping
0-60 s (2 s, default value).
Electric
Power Supply
HART: 16-42.4 Vdc (16-30 Vdc in IS applications, 20-42.4 Vdc in Explosion-proof / Flameproof applications).
F
OUNDATION
Fieldbus: 9-32 Vdc (9-30 Vdc in IS applications, and 16-32 Vdc in Explosionproof / Flameproof
applications).
FISCO, IS applications: 9-17.5 Vdc.
Internal Power
Consumption
< 50 mW in normal operation.
Output
HART 4-20 mA current loop or F
OUNDATION
Fieldbus.
Quiescent Current Draw (
F
OUNDATION
Fieldbus)
21 mA
Signal on Alarm
Standard : Low = 3.75 mA, High = 21.75 mA.
Namur NE 43: Low = 3.60 mA, High = 22.50 mA.
Saturation Levels
Standard: Low = 3.9 mA, High = 20.8 mA.
Namur NE 43: Low = 3.8 mA, High = 20.5 mA.
IS Parameters
See Appendix B: Product Certifications.
Cable Entry
½ - 14 NPT for cable glands or conduit entries.
Optional: M20 x 1.5 conduit / cable adapter, M12 4-pin male eurofast
®
connector or A size Mini 4-pin male
minifast
®
connector.
Output Cabling
Twisted shielded pairs, 18-12 AWG.
Mechanical
Probes
Coaxial: 1.3 ft (0.4 m) to 19.7 ft (6 m).
Rigid Twin Lead: 1.3 ft (0.4 m) to 9.8 ft (3 m).
Flexible Twin Lead: 3.3 ft (1 m) to 164 ft (50 m).
Rigid Single Lead (0.3 in./8 mm): 1.3 ft (0.4 m) to 9.8 ft (3 m)
Rigid Single Lead (0.5 in./13 mm): 1.3 ft (0.4 m) to 14.8 ft (4.5 m)
Flexible Single Lead: 3.3 ft (1 m) to 164 ft (50 m).
Tensile Strength
4 mm Flexible Single Lead probe (model code 5A, 5B): 2698 lb (12 kN)
6 mm Flexible Single Lead probe (model code 6A, 6B): 6519 lb (29 kN)
Flexible Twin Lead probe: 2023 lb (9 kN).
Collapse Load
4 mm Flexible Single Lead probe (model code 5A, 5B): 3597 lb (16 kN)
6 mm Flexible Single Lead probe (model code 6A, 6B): 7868 lb (35 kN)
Sideway Capacity
Coaxial: 73.7 ft lbf or 3.7 lb at 19.7 ft (100 Nm or 1.67 kg at 6 m).
Rigid Twin Lead: 2.2 ft lbf or 0.22 lb at 9.8 ft (3 Nm or 0.1 kg at 3 m).
Rigid Single Lead: 4.4 ft lbf or 0.44 lb at 9.8 ft (6 Nm or 0.2 kg at 3 m).
Material Exposed to Tank
Atmosphere
• 316L SST (EN 1.4404), PTFE, PFA
(5)
and O-ring materials (Standard Probe, Material model code 1) or
• Alloy C-276 (UNS N10276), PTFE, PFA
and O-ring materials (Standard Probe, Material model code 2) or
• Alloy 400 (UNS N04400), PTFE, PFA
and O-ring materials (Standard Probe, Material model code 3)
• PTFE
(6)
(Standard Probe, Material model code 7) or
• PTFE
, 316 L SST (EN 1.4404) and O-ring materials (Standard Probe, Material model code 8)
• 316L SST (EN 1.4404), Ceramic (Al
2
O
3
), Graphite, Inconel (HTHP Probe, Material model code 1)
• Alloy C-276 (UNS N10276), Ceramic (Al
2
O
3
), Graphite, Inconel (HTHP Probe, Material model code 2 and H)
• 316L SST (EN 1.4404), Ceramic (Al
2
O
3
), Graphite, PFA, PTFE, Inconel (HP Probe, Material model code 1)
• Alloy C-276 (UNS N10276), Ceramic (Al
2
O
3
), Graphite, PFA, PTFE, Inconel (HP Probe, Material model code
2 and H)
• 316L SST (EN 1.4404), Ceramic (Al
2
O
3
), Graphite, PFA, PTFE, Inconel (C Probe, Material model code 1)