Rosemount 5300 series, Reference manual – Emerson Process Management ROSEMOUNT 5300 User Manual
Page 284
Reference Manual
00809-0100-4530, Rev BA
July 2009
Rosemount 5300 Series
F-4
TCL
37
This parameter is used for User Defined probes only. Please
contact Emerson Process Management Service Department
for more information
PROPAGATION_FACTOR
38
This parameter is used for User Defined probes only. Please
contact Emerson Process Management Service Department
for more information
REF_PULSE_AMPL
39
This parameter is used for User Defined probes only. Please
contact Emerson Process Management Service Department
for more information
GEOM_TANK_HEIGHT
40
Tank Height (R)
GEOM_HOLD_OFF_DIST
41
Hold off distance
VAPOR_DC
42
Enter the dielectric constant for the vapor gas in the tank. For
air at 20 degC and atmospherical pressure the vapor DC is
close to 1, but for high pressure/high temperature applications
the DC may increase and affect the accuracy of the
measurement
UPPER_PRODUCT_DC
43
Enter the Upper Product Dielectric Constant (DC) as dielectric
accurate as possible. This value affects the accuracy of the
interface level measurement
LOWER_PRODUCT_DC_RANGE
44
Enter the range of the dielectric constant (DC) for the lower
product in the tank. If you are uncertain about the value for
this parameter or are changing product in the tank on a
regular basis choose Unknown
PRODUCT_DIELEC_RANGE
45
Enter the range of the Product DC for the product in the tank.
If you are uncertain about the value for this parameter or are
changing product in the tank on a regular basis choose
Unknown
MEAS_MODE
46
Select the Measurement Mode to use in the device. Some
modes require software options to be enabled in the device.
You can upgrade the device to enable more software options
DAMP_VALUE
47
Damping value
GEOM_OFFSET_DIST
48
Distance Offset
GEOM_CALIBRATION_DIST
49
Calibration Distance
LCD_SETTINGS
50
LCD_PARAMETERS
51
Parameters to show
LCD_LANGUAGE
52
Language on display
LCD_LENGTH_UNIT
53
Length unit on display
LCD_VOLUME_UNIT
54
Volume unit on display
LCD_TEMPERATURE_UNIT
55
Temperature unit on display
LCD_VELOCITY_UNIT
56
Velocity unit on display
MAX_INTERNAL_TEMPERATURE
57
The maximum temperature that has been measured inside
the device during operation
MIN_INTERNAL_TEMPERATURE
58
The minimum temperature that has been measured inside the
device during operation
OPERATION TIME
59
The total number of hours the device has been in operation
ENV_ENVIRONMENT
60
Process Condition
ENV_PRESENTATION
61
Tank Presentation
ENV_DEVICE_MODE
62
Service mode
ENV_WRITE_PROTECT
63
Write protect
DIAGN_DEVICE_ALERT
64
Errors, Warnings, Status, Plant web alerts
DIAGN_VERSION
65
Gauge SW version
DIAGN_REVISION
66
P1451 revision
DIAGN_DEVICE_ID
67
Device ID for the gauge.
DIAGN_DEVICE_MODEL
68
Type of 5300. LF or HF
STATS_ATTEMPTS
69
The total number of messages sent to the transducer A/D
board
STATS_FAILURES
70
The total number of failed A/D board message attempts
Parameter
Index Number
Description