I-2
CYCLE_TYPE
19
Identifies the block execution methods available for this resource.
DD_RESOURCE
09
String identifying the tag of the resource which contains the Device Description for
this resource.
DD_REV
13
Revision of the DD associated with the resource - used by an interface device to locate
the DD file for the resource.
DEFINE_WRITE_LOCK
60
Allows the operator to select how WRITE_LOCK behaves. The initial value is “lock
everything”. If the value is set to “lock only physical device” then the resource and
transducer blocks of the device will be locked but changes to function blocks will be
allowed.
DETAILED_STATUS
55
Indicates the state of the transmitter. See Resource Block detailed status codes.
DEV_REV
12
Manufacturer revision number associated with the resource - used by an interface device
to locate the DD file for the resource.
DEV_STRING
43
This is used to load new licensing into the device. The value can be written but will
always read back with a value of 0.
DEV_TYPE
11
Manufacturer’s model number associated with the resource - used by interface devices
to locate the DD file for the resource.
DIAG_OPTION
46
Indicates which diagnostics licensing options are enabled.
DISTRIBUTOR
42
Reserved for use as distributor ID. No Foundation enumerations defined at this time.
DOWNLOAD_MODE
67
Gives access to the boot block code for over-the-wire downloads.
0 = Uninitialized
1 = Run mode
2 = Download mode
FAULT_STATE
28
Condition set by loss of communication to an output block, fault promoted to an output
block or physical contact. When FAIL_SAFE condition is set, then output function blocks
will perform their FAIL_SAFE actions.
FAILED_ACTIVE
72
Enumerated list of failure conditions within a device.
FAILED_ALM
73
Alarm indicating a failure within a device which makes the device non-operational.
FAILED_ENABLE
70
Enabled FAILED_ALM alarm conditions. Corresponds bit for bit to the FAILED_ACTIVE.
A bit on means that the corresponding alarm condition is enabled and will be detected. A
bit off means the corresponding alarm condition is disabled and will not be detected.
FAILED_MASK
71
Mask of FAILED_ALM. Corresponds bit of bit to FAILED_ACTIVE. A bit on means that
the condition is masked out from alarming.
FAILED_PRI
69
Designates the alarming priority of the FAILED_ALM.
FB_OPTION
45
Indicates which function block licensing options are enabled.
FEATURES
17
Used to show supported resource block options.
The supported features are: SOFT_WRITE_LOCK_SUPPORT,
HARD_WRITE_LOCK_SUPPORT, REPORTS, and UNICODE
FEATURES_SEL
18
Used to select resource block options.
FINAL_ASSY_NUM
54
The same final assembly number placed on the neck label.
FREE_SPACE
24
Percent of memory available for further configuration. Zero in a preconfigured device.
FREE_TIME
25
Percent of the block processing time that is free to process additional blocks.
GRANT_DENY
14
Options for controlling access of host computers and local control panels to operating,
tuning, and alarm parameters of the block. Not used by device.
HARD_TYPES
15
The types of hardware available as channel numbers.
HARDWARE_REV
52
Hardware revision of the hardware that has the resource block in it.
HEALTH_INDEX
84
Parameter representing the overall health of the device, 100 being perfect and 1 being
non-functioning. The value is based on the active PWA alarms.
ITK_VER
41
Major revision number of the inter operability test case used in certifying this device as
interoperable. The format and range are controlled by the Fieldbus Foundation.
LIM_NOTIFY
32
Maximum number of unconfirmed alert notify messages allowed.
MAINT_ACTIVE
77
Enumerated list of maintenance conditions within a device.
Parameter