background image

Reference Manual

00809-0100-4530, Rev BA
July 2009

A-5

Rosemount 5300 Series

Figure A-2. Maximum process
temperature and pressure
diagram for HTHP tank
connection.

Figure A-3. Maximum process
temperature and pressure
diagram for HP tank connection.

Figure A-4. Process
temperature and pressure
diagram for C tank connection

The HTHP, HP, and C versions have a ceramic tank seal, and graphite
gaskets - no O-rings are used. The final rating depends on flange selection.

A difference between the HP/C and HTHP coaxial versions is material for
some parts; PFA/PTFE for HP/C, and ceramics for HTHP. Ceramic spacers
allow for usage in applications with higher temperature.

The following table gives the temperature ranges for tank seal with different
O-ring material (applicable for the Standard Tank Connection):

Temperature
°F (°C)

Pressure psig (bar)

HTHP tank
connection

Temperature °F (°C)

Pressure psig (bar)

HP tank
connection

-200 (-129)

-320 (-196)

Pressure psig (bar)

C tank
connection

Temperature °F (°C)