beautypg.com

Plc inputs/outputs, Technical data, 11 plc inputs/outputs – HEIDENHAIN TNC 335 Technical Manual User Manual

Page 65: 1 technical data

background image


3-40

TNC 360

11 PLC inputs/outputs

8/95

11 PLC inputs/outputs

The HEIDENHAIN contouring control TNC 360 C has a capacity of max. 119 PLC inputs and 62 PLC
outputs.

55 PLC inputs and 31 PLC outputs can be connected directly to the logic unit. One PLC I/O board
(model PL 410 B or PL 410), with 64 PLC inputs and 31 PLC outputs, can be connected to the logic
unit.

11.1 Technical data

PLC inputs

Logic unit/ PL 410

PL 410 B

PL 400

Potential range

”1” signal: U

i

13 V to 30.2 V

13 V to 30.2 V

16.5 V to 30 V

”0” signal: U

i

–20 V to 3.2 V

–20 V to 3.2 V

–20 V to 4 V

Current range

”1” signal: I

i

3.8 mA to 8.9 mA

2.5 mA to 6 mA

6.2 mA to12.6 mA

”0” signal: I

i

1.0 mA at U

i

= 3.2 V

0.65 mA at U

i

= 3.2 V

1.6 mA at U

i

= 4 V

PLC outputs

Transistor outputs with current limiting

Logic unit

PL 410 B/ PL 410 / PL 400

Min. output potential
for ”1” signal

3 V below supply voltage

Nominal operating
current per output

0.1 A

1.2 A

Permissible load: resistive load, inductive load only with a quenching diode parallel to the inductance.
No more that half of the outputs may be switched on at simultaneously.

It is not permissible to short-circuit several outputs from the logic unit simultaneously.
A single short circuit does not cause an overload.