Plc inputs/outputs, Technical data, 11 plc inputs/outputs – HEIDENHAIN TNC 335 Technical Manual User Manual
Page 65: 1 technical data
3-40
TNC 360
11 PLC inputs/outputs
8/95
11 PLC inputs/outputs
The HEIDENHAIN contouring control TNC 360 C has a capacity of max. 119 PLC inputs and 62 PLC
outputs.
55 PLC inputs and 31 PLC outputs can be connected directly to the logic unit. One PLC I/O board
(model PL 410 B or PL 410), with 64 PLC inputs and 31 PLC outputs, can be connected to the logic
unit.
11.1 Technical data
PLC inputs
Logic unit/ PL 410
PL 410 B
PL 400
Potential range
”1” signal: U
i
13 V to 30.2 V
13 V to 30.2 V
16.5 V to 30 V
”0” signal: U
i
–20 V to 3.2 V
–20 V to 3.2 V
–20 V to 4 V
Current range
”1” signal: I
i
3.8 mA to 8.9 mA
2.5 mA to 6 mA
6.2 mA to12.6 mA
”0” signal: I
i
1.0 mA at U
i
= 3.2 V
0.65 mA at U
i
= 3.2 V
1.6 mA at U
i
= 4 V
PLC outputs
Transistor outputs with current limiting
Logic unit
PL 410 B/ PL 410 / PL 400
Min. output potential
for ”1” signal
3 V below supply voltage
Nominal operating
current per output
0.1 A
1.2 A
Permissible load: resistive load, inductive load only with a quenching diode parallel to the inductance.
No more that half of the outputs may be switched on at simultaneously.
It is not permissible to short-circuit several outputs from the logic unit simultaneously.
A single short circuit does not cause an overload.