3-16

TNC 360

4 Power Supply

8/95

X24 power supply for the PLC at the LE

Pin Number

Assignment

1

+ 24 Vdc switched off by EMERGENCY STOP

2

+ 24 Vdc not switched off by EMERGENCY STOP

3

0 V

Danger to internal components!
Use only original replacement fuses.

Power supply for the PL 410 B

The PLC outputs are powered in groups.

Terminal

Assignment

PLC output

X9

0V

X10

+24 V power for logic and for "Control is operational"

X11

+24 V power for outputs

O32 to O39

X12

O40 to O47

X13

O48 to O55

X14

O56 to O62

Power supply for the PL 410
Connections as with PL 410 B.

Terminal

Assignment

X13

+24 Vdc switched off by EMERGENCY STOP

X12

0 V

X3 Pin 12

+ 24 Vdc not switched off by EMERGENCY STOP

4.1.3 Buffer battery

The buffer battery is the potential source for the RAM memory for NC programs, PLC programs
and machine parameters when the control is switched off.

If the ”EXCHANGE BUFFER BATTERY” message appears, the batteries must be exchanged.

The 3 batteries may be found behind a screw cap in the power supply section of the logic unit.
As well as the batteries, the logic unit contains an additional energy store, mounted on the
processor board, for buffering the memory contents.

This means that the mains can be switched off when replacing the batteries. The energy
store will ensure that the memory is retained while the batteries are exchanged.