beautypg.com

HEIDENHAIN TNC 335 Technical Manual User Manual

Page 353

background image


4/96

TNC 360

3 List of Machine Parameters

5-9

Machine
parameter

Function and input

Reaction /
CN 123

Page

MP1110

Standstill monitoring
Input range: 0.001 to 30 [mm]

4-72

MP1140

Movement monitoring
Input value: 0.03 to 10 [V]

4-71

MP1150

Delay time before switching off the residual
voltage on error message "Position error"
Input value: 0 to 65.535 [s]

4-70

MP1220

Automatic cyclical offset adjustment
Input value 0 to 65 536 [s]

0 = no automatic adjustment

4-63

MP1320

Direction for traversing the reference marks
Input range: 0 to 15

Bit 0

Axis X

+0 = positive
+1 = negative

Bit 1

Axis Y

+0 = positive
+2 = negative

Bit 2

Axis Z

+0 = positive
+4 = negative

Bit 3

4th axis +0 = positive

+8 = negative

4-48

MP1330.0
to
MP1330.3

Feed rate for traversing the reference marks

Input range: 80 to 30 000 [mm/min]

4-48

MP1331.0
to
MP1331.3

Feed rate for leaving the reference end position
(only for rotary encoders MP1350 = 2)
Input range: 80 to 500 [mm/min]

4-48

MP1340.0
to
MP1340.3

Sequence for traversing reference marks
Input range: 0 to 4

0 = no evaluation of the reference marks
1 = axis X
2 = axis Y
3 = axis Z
4 = 4th axis

REF

4-48

MP1350.0
to
MP1350.3

Type of reference mark approach
Input range: 0 to 3

0 = measuring system with distance-coded

reference marks

1 = measuring system with one reference mark
2 = special sequence (linear measurement

via rotary encoder)

3 = measuring system with distance-coded

reference marks; after REF end position
traverse direction is changed

REF

4-49