3 List of Machine Parameters
5-9
Machine
parameter
Function and input
Reaction /
CN 123
Page
MP1110
Standstill monitoring
Input range: 0.001 to 30 [mm]
4-72
MP1140
Movement monitoring
Input value: 0.03 to 10 [V]
4-71
MP1150
Delay time before switching off the residual
voltage on error message "Position error"
Input value: 0 to 65.535 [s]
4-70
MP1220
Automatic cyclical offset adjustment
Input value 0 to 65 536 [s]
0 = no automatic adjustment
4-63
MP1320
Direction for traversing the reference marks
Input range: 0 to 15
Bit 0
Axis X
+0 = positive
+1 = negative
Bit 1
Axis Y
+0 = positive
+2 = negative
Bit 2
Axis Z
+0 = positive
+4 = negative
Bit 3
4th axis +0 = positive
+8 = negative
4-48
MP1330.0
to
MP1330.3
Feed rate for traversing the reference marks
Input range: 80 to 30 000 [mm/min]
4-48
MP1331.0
to
MP1331.3
Feed rate for leaving the reference end position
(only for rotary encoders MP1350 = 2)
Input range: 80 to 500 [mm/min]
4-48
MP1340.0
to
MP1340.3
Sequence for traversing reference marks
Input range: 0 to 4
0 = no evaluation of the reference marks
1 = axis X
2 = axis Y
3 = axis Z
4 = 4th axis
REF
4-48
MP1350.0
to
MP1350.3
Type of reference mark approach
Input range: 0 to 3
0 = measuring system with distance-coded
reference marks
1 = measuring system with one reference mark
2 = special sequence (linear measurement
via rotary encoder)
3 = measuring system with distance-coded
reference marks; after REF end position
traverse direction is changed
REF
4-49