beautypg.com

HEIDENHAIN TNC 335 Technical Manual User Manual

Page 250

background image


8/95

TNC 360

9 Touch Probe

4-153

Set

Reset

M2502

NC STOP in all operating modes if stylus
is deflected

PLC

PLC

M2503

Enable marker for probing functions

NC

PLC

M2022

Touch probe not ready (no standby
signal at connector X12)

NC

NC

M2023

Stylus deflected before start of probing
cycle

NC

NC

M2025

Stylus deflected (probing sequence is
executed)

NC

PLC

M2026

Probe operation ended or interrupted

NC

NC

M2027

Battery voltage too low (battery warning
on connector X12); evaluated only during
the probe operation

NC

NC

Example:
Enable of probing function in the PLC.

.
.
.

489

LN

I9

;I9 = 0 => TS not in holder

490

=

M2502 ;stop if stylus deflected

491

;

492

L

M2503

493

AN

I9

494

R

M2503 ;acknowledge probing cycle

495

;

496

;

497

;safety function

498

;M03/M04 deactivate if TS not in holder

499

;

500

L

M2485 ;M03 activated?

501

O

M2486 ;M04 activated?

502

AN

I9

;touch probe not in holder

503

S

M2487 ;display M05

504

R

M2485 ;deactivate M03

505

R

M2486 ;deactivate M04

506

R

M922

;clear buffered marker M03

507

R

M923

;clear buffered marker M04

508

R

M2488 ;NC stop