9.2.3 Optimizing the scanning sequence

The following preparations should be made before optimizing machine and controller.

- Set up the flat workpiece with vertical face and plane surface in the machining plane (e.g. XY

plane).

- Probe the surface with probing function "Surface = Datum" ("MANUAL" or "EL. HANDWHEEL

MODE") and enter the reference plane as +0 mm.

- Basic setting of the relevant machine parameters for "Digitizing"

MP6210

=

5 [1/s]

Oscillations in normal direction

MP6230

=

30 [mm/min]

Feed rate in normal direction

MP6240

=

5 [mm]

Maximum stylus deflection

- The interface must be configured according to the type of desired memory for the digitized data

(FE 401 or PC with "Block Transfer" program). See TNC 360 User's Manual.

- Connect FE 401 or PC to the serial data interface if necessary.

- Enter NC program with the scanning cycles "Range" and "Meander" and the scanning direction X

and the probe point interval 1 mm, e.g.

0

BEGIN PGM 1 MM

5

TCH PROBE 5.0 RANGE

Define the range

6

TCH PROBE 5.1 PGM NAME:2

to be digitized with

7

TCH PROBE 5.2 Z X+0 Y+0 Z-10

the program name for

8

TCH PROBE 5.3 X+100 Y+100 Z+10

the digitized data and

9

TCH PROBE 5.4 HEIGHT: +25

clearance height (absolute)

10

TCH PROBE 6.0 MEANDER

"Meander" scanning in X

11

TCH PROBE 6.1 DIRECTN:X

direction with stroke (for

12

TCH PROBE 6.2 TRAVEL:0.5 L.SPAC:1 P.P.INT:1

clearing steep edges), line

13

END PGM 1 MM

spacing and probe point
interval