beautypg.com

9 adjust the offset, 10 adjustment of the monitoring functions – HEIDENHAIN TNC 335 Technical Manual User Manual

Page 340

background image


8/95

TNC 360

16 Commissioning and Start-up Procedure

4-243

16.3.9 Adjust the offset

The rough offset adjustment has already been carried out on the servo amplifier. A fine offset
adjustment can be performed with the offset adjustment possibility described in Section "Servo
positioning".

16.3.10 Adjustment of the monitoring functions

The following entry values are recommended for the monitoring functions (see Section "Servo
positioning"):

Machine parameter Function

Entry value

MP1710

Position monitoring

1.2

×

lag in rapid traverse

MP1720

Position monitoring (EMERGENCY STOP)

1.4

×

lag in rapid traverse

MP1410

Position monitoring

0.5 [mm]

MP1420

Position monitoring (EMERGENCY STOP)

10 [mm]

MP1140

Movement monitoring

0.5 [V]

MP1030

Positioning window

0.01 [mm]

MP1110

Standstill monitoring

0.2 [mm]

If the drives of the machine permit narrower limits, these may be entered.