2.4.2 Counters

32 counters are available in the PLC. Each of these 32 counters is controlled by special markers with
the abbreviation symbol C. After setting a marker from the range C0 to C31 the counter is loaded
with the value from machine parameter MP4120.X. The marker range C48 to C79 indicates whether
the count has been completed or not. The marker range C96 to C127 is used to start the counter
(counter release pulse).

Example:

Logic diagram for counter C1
Contents of machine parameter MP4120.1 = 10 (PLC cycles)

C1

C49

C97

C0

C48

C96

MP4120.0

C1

C49

C97

MP4120.1

C2

C50

C98

MP4120.2

C3

C51

C99

MP4120.3

C4

C52

C100

MP4120.4

C5

C53

C101

MP4120.5

C6

C54

C102

MP4120.6

C7

C55

C103

MP4120.7

C8

C56

C104

MP4120.8

C9

C57

C105

MP4120.9

C10

C58

C106

MP4120.10

C11

C59

C107

MP4120.11

C12

C60

C108

MP4120.12

C13

C61

C109

MP4120.13

C14

C62

C110

MP4120.14

C15

C63

C111

MP4120.15

C16

C64

C112

MP4120.16

C17

C65

C113

MP4120.17

C18

C66

C114

MP4120.18

C19

C67

C115

MP4120.19

C20

C68

C116

MP4120.20

C21

C69

C117

MP4120.21

C22

C70

C118

MP4120.22

C23

C71

C119

MP4120.23

C24

C72

C120

MP4120.24

C25

C73

C121

MP4120.25

C26

C74

C122

MP4120.26

C27

C75

C123

MP4120.27

C28

C76

C124

MP4120.28

C29

C77

C125

MP4120.29

C30

C78

C126

MP4120.30

C31

C79

C127

MP4120.31

MP4120.x

Pre-set value for counters C0 to C31