beautypg.com

HEIDENHAIN TNC 335 Technical Manual User Manual

Page 213

background image


4-116

TNC 360

6 Display and Operation

8/95

MP7620

Feed rate override
Input: 0 to 7

Bit 0

Feed rate override if rapid traverse key is pressed in
a "Program run" mode
+0 =

Override not effective

+1 =

Override effective

Bit 2

Feed rate override if rapid traverse key and
machine axis direction key are pressed in the
"Manual" mode
+0 =

Override not effective

+4 =

Override effective

Bit 3

Spindle and feed rate override

in 1% increments or according to
a nonlinear curve
+0 =

1% increments

+8 =

Nonlinear curve

W494

% factor – feed rate override (NC

PLC)

W766

% factor – feed rate override (PLC

NC)

D596

Feed rate from PLC for feed rate limiting