beautypg.com

HEIDENHAIN TNC 335 Technical Manual User Manual

Page 359

background image


4/96

TNC 360

3 List of Machine Parameters

5-15

Machine
parameter

Function and input

Reaction /
CN 123

Page

MP5020

Operating mode EXT: interface configuration
Input range: 0 to 255

Bit 0

7 or 8 Data bits
+0 = 7 Data bits
+1 = 8 Data bits

Bit 1

Block Check Character
+0 = BCC character optional
+2 = BCC character not control character

Bit 2

Transmission stop through RTS
+0 = not active
+4 = active

Bit 3

Transmission stop through DC3
+0 = not active
+8 = active

Bit 4

Character parity
+0 = even
+16 = odd

Bit 5

Character parity
+0 = not required
+32 = required

Bit 6/7

Stop bits

Bit 6

Bit 7

+0 = 1½ Stop bits

0

0

+64 = 2 Stop bits

1

0

+128 = 1 stop bit

0

1

+192 = 1 stop bit

1

1

Bit 8

RTS in quiescent state low

Bit 9

No EOT after ETX received

CN 123

8-28

MP5030.0

Operating mode EXT: data transmission protocol
Input: 0 or 1

0 = "Standard data transmission"
1 = "Blockwise transfer"

CN 123

8-28

MP5040

Data transfer rate for PLC interface
Input range: 0 to 9

0 =

110 baud

5 =

2 400 baud

1 =

150 baud

6 =

4 800 baud

2 =

300 baud

7 =

9 600 baud

3 =

600 baud

8 = 19 200 baud

4 = 1200 baud

9 = 38 400 baud

CN 123

8-42