HEIDENHAIN TNC 335 Technical Manual User Manual
Page 359
4/96
TNC 360
3 List of Machine Parameters
5-15
Machine
parameter
Function and input
Reaction /
CN 123
Page
MP5020
Operating mode EXT: interface configuration
Input range: 0 to 255
Bit 0
7 or 8 Data bits
+0 = 7 Data bits
+1 = 8 Data bits
Bit 1
Block Check Character
+0 = BCC character optional
+2 = BCC character not control character
Bit 2
Transmission stop through RTS
+0 = not active
+4 = active
Bit 3
Transmission stop through DC3
+0 = not active
+8 = active
Bit 4
Character parity
+0 = even
+16 = odd
Bit 5
Character parity
+0 = not required
+32 = required
Bit 6/7
Stop bits
Bit 6
Bit 7
+0 = 1½ Stop bits
0
0
+64 = 2 Stop bits
1
0
+128 = 1 stop bit
0
1
+192 = 1 stop bit
1
1
Bit 8
RTS in quiescent state low
Bit 9
No EOT after ETX received
CN 123
8-28
MP5030.0
Operating mode EXT: data transmission protocol
Input: 0 or 1
0 = "Standard data transmission"
1 = "Blockwise transfer"
CN 123
8-28
MP5040
Data transfer rate for PLC interface
Input range: 0 to 9
0 =
110 baud
5 =
2 400 baud
1 =
150 baud
6 =
4 800 baud
2 =
300 baud
7 =
9 600 baud
3 =
600 baud
8 = 19 200 baud
4 = 1200 baud
9 = 38 400 baud
CN 123
8-42