beautypg.com

HEIDENHAIN TNC 335 Technical Manual User Manual

Page 532

background image


8/95

TNC 360

2 TNC data interfaces

8-25

MP 5020

Operating mode EXT: Interface configuration
Input range: 0 to 255

Bit 07 or 8 data bits

+0 = 7 data bits
+1 = 8 data bits

Bit 1Block check character

+0 = any BCC
+2 = BCC not control character

Bit 2Transmission stop by RTS

+0 = not active
+4 = active

Bit 3Transmission stop by DC3

+0 = not active
+8 = active

Bit 4Character parity

+0 = even
+16 = uneven

Bit 5Character parity

+0 = not desired
+ 32 = desired

Bit 6/7

Stop bits

Bit 6

Bit 7

+0 = 1 1/2 stop bits

Bit

0

0

+64 = 2 stop bits

Bit Bit

1

0

+128 = 1 stop bit

Bit Bit

0

1

+192 = 1 stop bit

Bit Bit

1

1

For operating modes EXT, MP5030 defines the transmission protocol.

MP5030.0

Operating mode EXT: Data transfer protocol
Input: 0 or 1

0 = "Standard data transfer"
1 = "Transfer blockwise"