3-30

TNC 360

8 Touch Probe System Input

8/95

8.2.2 TS 511

The TS 511 touch probe system can only function together with a transmitter/receiver unit (SE 510)
and interface electronics (APE 510).

Touch probe input

Internal screen (0V)

Standby
Start
15V

±

10% (U

P

)

Battery warning
0V (U

N

)

Trigger signal

X12

Id.-Nr. 274 539 ..

max. 7 m

max. 30 m

Id.-Nr. 274 540 ..

SE 510

3 m

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

APE

510

7
5
3
2
6
1
4

GY
YL
BN

BL
WH

GN

1
2
3
4
5
6
7

1
2
3
4
5
6
7

1
2
3
4
5
6
7

GY
YL
BN
WH
GN
BL

WH
BN

GY

GN

WH/
BK

0V

U

P

Flash signal

IR-signal

Internal

screen (0V)

SE 510

WH/BN

APE 510

WH/
BK

RD

The signals may be inverted by changing the switch positions S1 to S4 in the APE 510.
See the operating instructions for the TS 511.

Please install the transmitter/receiver unit SE 510 either insulated from, or electrically connected to
the machine, as it must take up a definite potential, also under vibration. The earthing screw of
the APE 510 must be joined to the machine signal ground by a potential compensating lead
(

6 mm²).