HEIDENHAIN TNC 335 Technical Manual User Manual
Page 219

4-122
TNC 360
6 Display and Operation
8/95
The dialogs for PLC error messages can be determined by the manufacturer of the machine. Please
contact HEIDENHAIN about this. The standard version has dialogs with the reserved designations
"PLC: ERROR 0" to "PLC: ERROR 99". These PLC error messages can be activated by the PLC
markers M2924 to M3023.
The error messages can be canceled either by pressing the CE key or by resetting the appropriate
markers.
If several PLC error messages are activated simultaneously, they can be read out one after another
by pressing the CE key.
If the program run is to be stopped on output of a PLC error message, this must be explicitly
programmed in the PLC program (NC STOP).
In order to show a PLC error message as a flashing message, the marker M2815 must also be set.
If marker M2815 is set, but none of the 100 PLC error messages is activated, then the flashing error
message "EMERGENCY STOP PLC" will be displayed.
If, for some reason, the display of the PLC error message is not wanted in the field under the
operating-mode display, the message can also be displayed in the PLC window.
Marker
Function
Set
Reset
M2815
Flashing PLC error message
PLC
PLC
M2190
Non-flashing error message
NC
NC
M2924
PLC error message 0
PLC
NC;PLC
M2925
PLC error message 1
M2926
PLC error message 2
M2927
PLC error message 3
M2928
PLC error message 4
M2929
PLC error message 5
M2930
PLC error message 6
M2931
PLC error message 7
M2932
PLC error message 8
M2933
PLC error message 9
M2934
PLC error message 10
M2935
PLC error message 11
M2936
PLC error message 12
M2937
PLC error message 13
M2938
PLC error message 14
M2939
PLC error message 15
M2940
PLC error message 16
M2941
PLC error message 17
M2942
PLC error message 18
M2943
PLC error message 19
M2944
PLC error message 20
M2945
PLC error message 21
M2946
PLC error message 22
M2947
PLC error message 23
M2948
PLC error message 24
M2949
PLC error message 25
M2950
PLC error message 26
M2951
PLC error message 27