beautypg.com

4 display of m functions, 5 display of run duration – HEIDENHAIN TNC 335 Technical Manual User Manual

Page 214

background image


8/95

TNC 360

6 Display and Operation

4-117

6.3.4 Display of M functions

The miscellaneous functions for control of the spindle (M03, M04, M05) and the coolant (M08, M09)
are displayed in the status display. The display of these M functions is controlled by the PLC, i.e. the
machine tool builder must take this into account when creating the PLC program. The markers
M2485 and M2486 also change the polarity of the analog voltage for the spindle. M2608 switches
off the analog output for the spindle. The programmed spindle speed is, however, still displayed (see
section "Spindle").

Marker

Function

Set

Reset

M2485

Status display and sign of S analog for M03 PLC

PLC

M2486

Status display and sign of S analog for M04

M2487

Status display for M05 and spindle stop

M2508

Status display M08 or M09
0 = Status display M09
1 = Status display M08

M2608

Status display M03, M04, M05 inverse and
S analog output = 0V

M2609

Status display M08, M09 inverse

6.3.5 Display of run duration

The TNC has three timers that measure the duration in seconds of the following states:
– Control (dialog "Control on")
– Program run (dialog "Program run")
– Spindle (dialog "Spindle on")

Control on
This timer starts with the first PLC run after the control reset.

Program run
This timer measures the duration of program run (see User's Manual TNC 360).

Spindle
The spindle operating time starts when the Markers M2485/M2486 are set and stops when they are
reset.

Display of run duration
The three timers can be called by entering the code number 85 7282 (see User's Manual TNC 360)
and can then be reset, depending on MP 7235.

Resetting the run duration timers
All timers are kept in the battery-buffered RAM and are reset after the error message "Operation
parameters erased."