beautypg.com

Touch probe system input, Connector assignment, 8 touch probe system input – HEIDENHAIN TNC 335 Technical Manual User Manual

Page 55: 1 connector assignment x12

background image


3-28

TNC 360

8 Touch Probe System Input

8/95

8 Touch Probe System Input

The 3D touch probe systems from HEIDENHAIN can be delivered in two versions:
– TS 120 with cable transmission and integrated APE interface electronics
– TS 511 with infrared transmission of the trigger signal and connectable via APE interface
electronics

For start-up and adjustment of the 3D touch probe systems see Chapter "Machine Integration".

8.1 Connector assignment

X12

X12 Touch probe system TS 120/TS 511

Flange socket with female connector insert (15-pin)

Pin Number

Signal designation

1

Inner screen (0 V)

3

Ready/standby

4

Start

5

+15 V ± 10 % (U

P

)

6

+ 5 V ± 5 % (U

P

)

7

Battery warning

8

0 V (U

N

)

9

Trigger signal

10

Trigger signal

2

2, 11 to 15

Do not use

2 Stylus in rest position = signal high