beautypg.com

Verilink 8100A (34-00237) Product Manual User Manual

Page 244

background image

7-6

8 0 0 0 S e r i e s

IAD is improperly
provisioned at the
voice gateway

Incorrect network
provisioning

Incorrect directory
number at the Class 5
switch

Verify and correct
provisioning of IAD as
required (refer to page 5-2).

Check and correct network
provisioning at DSLAM,
network switches, etc.

Check and correct as required

Cannot receive or send data

Incorrect PVC/DLCI
set for data channel

Verify these settings:

VPI: 0 to 255

VCI: 0 to 65535

DLCI: 16 to 1023

(default PVC 0/38; DLCI 32)

View Interface (page 5-13)
and Media statistics
(page 5-22) to check the pack
receive and send status.

Incorrect network
setup

Check and correct network
setup as necessary.

If IAD is configured as a router:

Incorrect or missing
LAN or WAN IP
address

Ensure that both the LAN and
WAN IP addresses are
configured.

Incorrect or missing
default static route

Review the routing table and
correct as necessary
(page 5-31).

Incompatible RIPv1

Check and correct subnet
masks (255.255.255.0)

Update RIPv1 to RIPv2.

If IAD is configured as a bridge:

Incorrect bridging
parameters

Review IAD configuration
(page 5-2) and current bridge
status (page 5-32).

Correct as necessary

Incorrect connection

Ensure the IAD is connected
to another bridge

Missing peer or
converter

Install a converter to convert
1483 cells to Ethernet packets.

Symptom

Probable Cause

Corrective Action