Display ethernet statistics, Display ethernet statistics -29 – Verilink 8100A (34-00237) Product Manual User Manual
Page 213
R e p o r t s
5-29
Display Ethernet Statistics
This report displays Ethernet statistics.
Parameter
Description
Received Packet Information
packets rcvd
Total Ethernet packets received
discarded, RX ring empty
Discarded received packets because the internal
Received Packet Ring Pool Buffers are empty;
therefore no incoming packets could be processed
discarded, unrecognized
protocol
Protocol Type field value in Ethernet header does not
correspond to IP
discarded, RX error
No. of discarded received packets due to the following
reasons:
- Alignment Errors - Frames containing a no. of bits
not divisible by eight is received and discarded.
- Bad FCS - Received frame contains CRC errors in
the header
- Runt - Received frame is smaller than the minimum
defined for this interface
- Giant - Received frame lengths are greater than
maximum defined for this interface
- Late Collision - Discarded frames because a collision
occurred during frame reception. No. of times that a
collision is detected on a particular interface later than
512 bit-times into the transmission of a packet
- Overrun - Discarded received packets due to the
internal Received Packet Ring Pool are full; therefore
no incoming packets could be processed
Sent Packet Information
packets sent
Total Ethernet packets sent.
discarded, TX ring full
Discarded outgoing packets due to full internal
Transmitted Packet Ring Pool Buffers. Could not
process any outgoing packets
discarded, bad pkt
Length of outgoing packets is larger than the
maximum length of this interface
- 8108 Series IAD (34-00339.B) Product Manual 8508 Series IAD (34-00339.B) Product Manual 8208 Series IAD (34-00339.B) Product Manual 8308 Series IAD (34-00339.B) Product Manual 7500p Series IAD (34-00334.B) Product Manual 7200p Series IAD (34-00334.B) Product Manual 7000 Series (34-00334) Product Manual