beautypg.com

Comtech EF Data SDM-300L3 User Manual

Page 384

background image

SDM-300L3 Satellite Modem

Revision 1

Remote Control Operation

MN/SDM300L3.IOM

A–32

Bulk Consol.
Analog
Status

Command:
Response:

>add/BCAS_p1,p2,p3, . . . pn'cr''lf']


This command is similar to the 'BCS_' command, but
returns modem analog parameters. Additional status
of new options and features will always be appended
to the end.

Where 'pn' is the last parameter returned.

Parameter
Number

Parameter Name
(Command Reference)


Description

1

2

3

4

5

6

7

8

Receive Signal Level
(ref. 'RSL_' command).
Raw BER
(ref. 'RBER_' command).
Corrected BER
(ref. 'CBER_' command).
Interface Read Error Status
(ref. 'IRES_' command).
EB/N0
(ref. 'EBN0_' command).
Buffer Fill Status
(ref. 'IBFS_' command).
LNB Current
(ref. LNBC_’ command).
ODU Current
(ref. ODUC_’ command).

p1 = xsnn.n, receive signal level in dBm.

p2 = xm.mE-ee.

p3 = xm.mE-ee.

p4 = tttt_xm.mE-ee.

p5 = xnn.n, EB/N0 in dB.

p6 = nn%, buffer fill status.

P7 = nnn, LNB Current

P8 = nnnn, ODU Current

Note: Parameters 2 through 6 are dependent on carrier acquisition, if the decoder is not locked empty data blocks are returned (,,,,,).