Demodulation and FEC Decoding Types
The following combinations of demodulation and forward error correction decoding are
available.
Table 14-8. L-Band Demodulation and FEC Decoding Types
Decoder
Code Rate
Reed Solomon
Modulation
Viterbi, K7
1/2
BPSK
Viterbi, K7
1/2
225/205 Closed
BPSK
Viterbi, K7
1/2 ,3/4, 7/8
QPSK, OQPSK
PTCM 2/3
8-PSK
Viterbi, K7
1/2, 3/4, 7/8
225/205 [4] IDR T1
225/205 [8] No Overhead, ASYNC Overhead
219/201 [4] VSAT IBS, IBS, IDR E1
126/112 [4] IDR Small Carrier, SDM-300 Legacy
QPSK, OQPSK
PTCM
(RS EFD Compatible)
2/3
225/205 [ ] Closed or IDR T1,
126/112 [ ] IBS and D&I,
219/201 [ ] IDR E1
8-PSK
PTCM
(RS IESS-310 Compatible)
2/3
219/201 [4] No Overhead, 219/201 [4] IBS and
D&I,
219/201 [8] IDR T1/E1
8-PSK
Sequential 1/2
BPSK
Sequential
1/2
225/205 [ ] Closed
BPSK
Sequential
1/2. 3/4, 7/8
QPSK, OQPSK
Sequential
1/2, 3/4, 7/8
225/205 [ ] Closed
QPSK, OQPSK
Uncoded 1/1
BPSK,
QPSK
Turbo Product
21/44, 5/16
BPSK
Turbo Product
1/2, 3/4
QPSK, OQPSK
Turbo Product
3/4
8-PSK
Note: Interleaver depths are selectable at: 4, 8, or 16. The values shown are default or Open Network