Comtech EF Data SDM-300L3 User Manual

Page 369

background image

SDM-300L3 Satellite Modem

Revision 1

Remote Control Operation

MN/SDM300L3.IOM

A–17

A.3.6

MUX PCB Configuration Commands (MUX PCB Installed Only)

Mux
Tributary
Data Rate &
Enable

Command:
Response:

Status:
Response:

>add/MTDR_x_yyyyyy'cr''lf']

>add/MTDR_x_yyyyyy'cr''lf']

Where:

x = 1 to 8 (tributary number).

yyyyyy = OFF (disabled), or 0.6 to 4000.0 (kbps in
100 bits steps).

Mux
Tributary
Interface
Type

Command:
Response:

Status:
Response:

>add/MTIT_x_yyyyy'cr''lf']

>add/MTIT_x_yyyyy'cr''lf']

Where:
x = 1 to 8 (tributary number).
yyyyy = RS422 or RS232.

Mux
Tributary
Clock
Phase

Command:
Response:

Status:
Response:

>add/MTCP_x_yyy'cr''lf']

>add/MTCP_x_yyy'cr''lf']

Where:

x = 1 to 8 (tributary number).

yyy = NRM (normal clock phasing), INV (inverted clock
phasing).

Mux
Tributary
Data Phase

Command:
Response:

Status:
Response:

>add/MTDP_x_yyy'cr''lf']

>add/MTDP_x_yyy'cr''lf']

Where:

x = 1 to 8 (tributary number).

yyy = NRM (normal data phasing), INV (inverted data
phasing).

Mux
Tributary
Mode

Command:
Response:

Status:
Response:

>add/MTMD_x_yyyyy'cr''lf']

>add/MTMD_x_yyyyy'cr''lf']

Where:
x = 1 to 8 (tributary number).
yyyyy = SYNC or ASYNC.

Mux
Tributary
Async
Format

Command:
Response:

Status:
Response:

>add/MTAF_x_yyy'cr''lf']

>add/MTAF_x_yyy'cr''lf']

Where:
x = 1 to 8 (tributary number).
yyy = 7E1, 7O1, 7N2, 7E2, 7O2, 8N1, or 8N2.