beautypg.com

Odu output power off, Odu pwr leveling off – Comtech EF Data SDM-300L3 User Manual

Page 178

background image

SDM-300L3 Satellite Modem

Revision 1

Front Panel Operation

MN/SDM300L3.IOM

4–110

FUNCTION SELECT: UTILITY: OUTDOOR UNIT:

ODU OUTPUT POWER (CONDITIONAL)

ODU OUTPUT POWER

OFF

IMPORTANT

Conditional: This menu is available only when ODU Power Supply, FSK,
and TX-IF Output are On.


Turns RF power at ODU/BUC On or Off. Select ODU Output Power On or Off.
Press [

] or [

] to select the ODU Output Power. Press [ENTER] to execute the change.

FUNCTION SELECT: UTILITY: OUTDOOR UNIT:

ODU PWR LEVELING (CONDITIONAL)

ODU PWR LEVELING

OFF


IMPORTANT

Conditional: This menu is available only when ODU Power Supply
and TX-IF Output are On.


When Power Leveling is On the Modem TX-IF Output is continually adjusted to maintain the ODU
Power level set by selecting ODU PWR Leveling = On. In the On mode the modem Auto adjusts
the ODU Power Level. This requires an FSK capable ODU (BUC). The Monitor menu shows the
actual BUC Power and (T) Target Power. Press [

] or [

] to select the ODU Power Leveling.

Press [ENTER] to execute the change.