beautypg.com

Function select: monitor, Function select: monitor: raw ber, Function select: monitor: corrected ber – Comtech EF Data SDM-300L3 User Manual

Page 129

background image

SDM-300L3 Satellite Modem

Revision 1

Front Panel Operation

MN/SDM300L3.IOM

4–61

4.6.2

FUNCTION SELECT: MONITOR

FUNCTION SELECT

MONITOR


Press to review or edit the following sub-menus.

FUNCTION

SELECT: MONITOR: RAW BER

RAW BER
2.4 E-3


Displays the current BER or “No Data” (if carrier is not locked).
Range: < m.m E-e to > m.m E-e.

Notes:

1. Low limit is based on performance.
2. High limit is based on data/code rate.


Press[

] or [

] to move the flashing cursor, and [

] or [

] to increment or decrement

the selected kbps. Press to execute the change.

FUNCTION

SELECT:

MONITOR: CORRECTED BER

CORRECTED BER

4.0

E-3


Displays the current corrected BER or “No Data” (if carrier is not locked).
Range: 1.0 E-3 to 1.0 E-12.

Notes:

1. Low limit is based on performance.
2. High limit is 1.0 E-12.


Press[

] or [

] to move the flashing cursor, and [

] or [

] to increment or decrement

the selected kbps. Press to execute the change.