beautypg.com

Remote cl action hold – Comtech EF Data SDM-300L3 User Manual

Page 118

background image

SDM-300L3 Satellite Modem

Revision 1

Front Panel Operation

MN/SDM300L3.IOM

4–50

FUNCTION SELECT:CONFIGURATION:LOCAL AUPC:
REMOTE CL ACTION (CONDITIONAL)

REMOTE CL ACTION

HOLD

IMPORTANT

Conditional: This menu is displayed when Local Modem AUPC = ON
located under the Utility: Modem Type menu.


Programs the Remote Carrier Loss action (CL) for HOLD, NOMINAL, or MAXIMUM.
The modulator carrier at the local end moves to this value upon carrier loss at the remote
end. This only applies to remote AUPC between two carriers.

HOLD

Upon Carrier Loss (CL) the carrier level remains at the level just before carrier
loss.

NOMINAL

Upon CL the TX Carrier Level reverts to the Nominal Power Level programmed
under Configuration: Local AUPC: Nominal Power

MAXIMUM

Upon CL the TX Carrier Level is programmed to the level programmed under
Configuration: Local AUPC: Maximum Power.