11.4.1 Valid

ASYNC

Baud

Rates

The ASYNC baud rates are limited by the terrestrial data rates. The following table
shows the relationships between data and baud rates.

If DR

15.999K

Maximum baud rate is 150

If DR

31.999K

Maximum baud rate is 300

If DR

63.999K

Maximum baud rate is 600

If DR

127.999K

Maximum baud rate is 1200

If DR

255.999K

Maximum baud rate is 2400

If DR

511.999K

Maximum baud rate is 4800

If DR

1023.999K

Maximum baud rate is 9600

If DR

2047.999K

Maximum baud rate is 19200

If DR

2048.999K

Maximum baud rate is 38400


The following table lists examples.

If DR = 8.000K

Baud rate can be 150 or lower

If DR = 16.000K

Baud rate can be 300 or lower

If DR = 32.000K

Baud rate can be 600 or lower

If DR = 64.000K

Baud rate can be 1200 or lower

If DR = 128.000K

Baud rate can be 2400 or lower

If DR = 256.000K

Baud rate can be 4800 or lower

If DR = 512.000K

Baud rate can be 9600 or lower

If DR = 1024.000K

Baud rate can be 19200 or lower

If DR = 2048.000K

Baud rate can be 38400 or lower

11.4.2

Front Panel Operation

For information on the additional front panel operations that are specific to the ASYNC
interface. The following menus are affected:

Configuration Interface

Configuration Local AUPC

Utility Interface

Remote AUPC Configuration

Remote AUPC Monitor