Comtech EF Data SDM-300L3 User Manual
Page 162

SDM-300L3 Satellite Modem
Revision 1
Front Panel Operation
MN/SDM300L3.IOM
4–94
Select one of four (A, B, C, or D) pre-defined receiver code/data rate combinations or a
variable rate selection (V).
Code Rate
Data Rate Range
Non-Turbo Requirements
BPSK 1/2
2.4 to 1250 kbps
{O}QPSK 1/2
4.8 to 2500 kbps
{O}QPSK 3/4
7.2 to 3750 kbps
QPSK 7/8
8.4 to 4375 kbps
8-PSK 2/3
64.0 to 5000 kbps
BPSK 1/1
4.8 to 2500 kbps
{O}QPSK 1/1
9.6 to 5000 kbps
Turbo Requirements
BPSK 21/44
2.4 to 1193.181 kbps
BPSK 5/16
2.4 to 781.25 kbps
{O}QPSK 1/2
4.8 to 2386.363 kbps
8-PSK 3/4
384 to 5000 kbps
Burst Mode Data Range
BPSK 5/16
2.4 to 781.25 kbps
(O)QPSK 1/2
4.8 to 2386.363 kbps
8-PSK 3/4
384 to 5000 kbps
Upon entry, the current receive rate is displayed with the flashing cursor on the first
character of the code rate on line 1. Line 2 displays the data rate. Press [
←
] or [
→
] to
make the selection. To select the currently defined variable data rate, select TX-V, and
press [ENTER] twice.
To change the rate using the variable rate selection, press [ENTER] when TX-V is
displayed. A flashing cursor is displayed on the first character of the coding type on
line 1. Press [
←
] or [
→
] to move the flashing cursor, and [
↑
] or [
↓
] to increment or
decrement the digit at the flashing cursor. Press [ENTER] to execute the change.
Notes:
1. When the RX rate has been programmed, the receiver is automatically turned off
to prevent swamping of other channels. To turn the receiver on, use the RX-IF
Output function.
2. Code Rate 3/4 not compatible with a combination of a CSC Closed Modulator
Type and Sequential Encoder.