beautypg.com

Comtech EF Data SDM-650B User Manual

Page 339

background image

SDM-650B Satellite Modem

Trojan Interface

Rev. 5

G–43

Character “c”: Demodulator fault status character 1.

Bit 6 = 1 always.
Bit 5 = Demodulator fault.
Bit 4 = Carrier detect status (0 for decoder lock).
Bit 3 through Bit 0 = Binary representation (0 to 10) of the
number of demodulator stored faults.

Character “d”: Demodulator fault status character 2.

Bit 6 = 1 always.
Bit 5 = Demodulator RF synthesizer fault.
Bit 4 = Descrambler fault.
Bit 3 = I-channel fault.
Bit 2 = Q-channel fault.
Bit 1 = Bit clock fault.
Bit 0 = BER threshold fault.

Character “e”: Common equipment fault status character 1.

Bit 6 = 1 always.
Bit 5 = M&C fault.
Bit 4 = Reference fault.
Bit 3 through Bit 0 = Binary representation (0 to 10) of the
number of common equipment stored faults.

Character “f”: Common equipment fault status character 2.

Bit 6 = 1 always.
Bit 5 = Battery fault.
Bit 4 = +5 volt fault.
Bit 3 = +12 volt fault.
Bit 2 = -12 volt fault.
Bit 1 = Overflow fault.
Bit 0 = Underflow fault.

G.6.4.5.16 Change Status

This command indicates that a change has or has not occurred on either the BCS_ or the
BCSF_ response since the last BCS_ or BCSF_ poll.

Command:

Response:

>add/CS_x”cr””lf”]

Where: x =

“@” = no change since last CS_ poll.
“A” = BCS_ response has changed since last CS_ poll.
“B” = BCSF_ response has changed since last CS_ poll.
“C” = Both responses have changed since last CS_ poll.