beautypg.com

B.2.8.1.2 modulator/coder configuration program – Comtech EF Data SDM-650B User Manual

Page 232

background image

Remote Control Operation

SDM-650B Satellite Modem

B–56

Rev. 6

B.2.8.1.2 Modulator/Coder Configuration Program

This command is used by the SMS-658 M:N protection switch to collect information that
is necessary to configure backup modems.

Command:

Response:

>add/MCP_”cr”
MF_nnn.nnnn”cr”

Modulator Frequency

MPO_snn.n”cr”

Modulator Power Offset

(See Note 1)

LPC_xxx”cr”

Local AUPC Enable (ON/OFF)

(See Note 2)

MOP_snn.n”cr”

Modulator Output Power

MR_nnn_mmmm.m”cr”

Modulator Rate

SE_xxx”cr”

Scrambler Enable (ON/OFF)

DENC_xxx”cr”

Differential Encoder (ON/OFF)

TC_xxx”cr”

Transmit Clock (INT/EXT)

BBL_xxx”cr”

Baseband Loopback (ON/OFF)

ILB_xxx”cr”

Interface Loopback (ON/OFF)

ICFT_xxxx”cr”

Coding Format Transmit

(AMI/HDB3/B6ZS/B8ZS)
TOBR_nnnnn”cr”

Transmit Overhead Baud Rate

OCCL_n”cr”

Overhead Channel Character Length

OCSB_n”cr”

Overhead Channel Stop Bits

OCP_xxxx”cr”

Overhead Channel Parity

(See Note 1)

ISP_xxx”cr”

Interface Substitution Pattern 2047 (ON/OFF)

(See Note 1)

LPC_xxx”cr”

Local AUPC Enable (ON/OFF)

(See Note 1)

NOMP_-nn.n”cr”

Nominal Power Value (-5.0 to -30.0)

(See Note 1)

MINP_-nn.n”cr”

Minimum Power Limit (-5.0 to -30.0)

(See Note 1)

MAXP_-nn.n”cr”

Maximum Power Value (-5.0 to -30.0)

(See Note 1)

LCL_xxxx”cr”

Local Carrier Loss (HOLD, NOM, MAX)

(See Note 1)

RCL_xxxx”cr”

Remote Carrier Loss (HOLD, NOM, MAX)

RF_xxx”cr””lf”]

RF Output (ON/OFF)


Notes:

1. Available with AUPC support hardware only.
2. Only returned if local AUPC is disabled (OFF).