B.2 asynchronous overhead interface support option, B.2.1 general, B.2.2 message structure – Comtech EF Data SDM-650B User Manual
Page 209

SDM-650B Satellite Modem
Remote Control Operation
Rev. 6
B–33
B.2 Asynchronous Overhead Interface Support Option
This section describes the remote control operation of the SDM-650B with the
asynchronous overhead channel unit option installed:
• Firmware
number: FW/0713-34L
• Software
version: 4.12A
B.2.1 General
Remote controls and status information are transferred via an RS-485 (optional RS-232-C)
serial communications link.
Commands and data are transferred on the remote control communications link as
US ASCII-encoded character strings.
The remote communications link is operated in a half-duplex mode.
Communications on the remote link are initiated by a remote controller or terminal. The
modem never transmits data on the link unless it is commanded to do so.
B.2.2 Message Structure
The ASCII character format used requires 11 bits/character:
• 1 start bit
• 7 information bits
• 1 parity bit (odd/even)
• 2 stop bits
Messages on the remote link fall into the categories of commands and responses.
Commands are messages which are transmitted to a satellite modem, while responses are
messages returned by a satellite modem in response to a command.
The general message structure is as follows:
• Start
Character
• Device
Address
• Command/Response
• End of Message Character