B.2.3.4 Set Modulator Output Power Level

Command:

Response:

>add/MOP_snn.n”cr””lf”]


Status Only: Response:

>add/MOP_snn.n”cr””lf”]

Where:

snn.n = +20.0 to -45.0, in 0.5 dB increments for 140 MHz modulator.
snn.n = +20.0 to -30.0, in 0.5 dB increments for 70 MHz modulator.


Notes:

1. Must be within 25.0 dB of the modulator power offset value (see MPO_) for the

140 MHz modulator, and within 10.0 dB of the modulator power offset for the
70 MHz modulator.

2. When local AUPC enable is programmed ON, the (MOP) Modulator Output

Power command is not allowed; only MOP status is allowed. See “LPC_”