The action at loss of lock is as follows (modem A loses carrier detect):

1. Modem A sets its power to Nominal, Hold, or Maximum, as specified by Carrier

Loss action.


2. Modem A sends Carrier Lost command to modem B.

3. Modem B sets its power to Nominal, Hold, or Maximum, as specified by Remote

Carrier Loss action.

Note: Local Carrier Loss has priority over Remote Carrier Loss.

F.4.2 Modem-to-Modem Channel for Remote M&C

This feature allows the user to monitor and control a remote modem location using the
front panel or serial port of the local modem.

The user has the ability to set or reset the following commands:

• Baseband

Loopback

• TX 2047 Pattern
• AUPC

Enable


The user has the ability to remotely monitor the Receive 2047 BER.