beautypg.com

B.1.4.7.2 corrected ber – Comtech EF Data SDM-650B User Manual

Page 199

background image

SDM-650B Satellite Modem

Remote Control Operation

Rev. 6

B–23

B.1.4.7 BER Status

B.1.4.7.1 Raw BER

Command:

Response:

>add/RBER_nnnnE-4”cr””lf”]

Where: nnnn = RBER or < 1.0 (lower limit).

Example: Request raw BER from modem 123.

Command:

<123/RBER_”cr”

Response:

>123/RBER_152E-4”cr””lf”]

Where: RBER = .0152 errors/bit.


Note: “No Data” is returned if no carrier is detected (decoder not locked).

B.1.4.7.2 Corrected BER

Command:

Response:

>add/CBER_nE-m”cr””lf”]

Example: Request corrected BER from modem 19.

Command:

<19/CBER_”cr”

Response:

>19/CBER_2E-5”cr””lf”]

Where: CBER = .00002 errors/bit.


Notes:

1. Corrected BER limits are lower < 1E-8, upper > 1E-3.
2. “No Data” is returned if no carrier is detected (decoder not locked).