SDM-650B Satellite Modem

Remote Control Operation

Rev. 6

B–41

B.2.4.2.1 Demodulator Filter Rate Assignment

Command:

Response:

>add/ADRx_nnn_mmmm.m”cr””lf”]


Status Only: Response:

>add/ADRx_nnn_mmmm.m”cr””lf”]

Where:

x = A, B, C, or D (Filter designator).
nnn = 1/2, 3/4, 7/8, or BP12 (Decoder rate).
mmmm.m = 9.6 to 4080.0 (Data rate).


Note: The parameters “nnn_mmmm.m” may be replaced by “N/A” to indicate “no
assignment.”

Example:

Command:

Response:

>add/ADRx_N/A”cr””lf”]

B.2.4.2.2 Select Demodulator Rate

Command:

Response:

>add/SDRx_”cr””lf”]

Status Only: (See DR command.)

Where: x = A, B, C, or D (Filter designator).


Note: If the modem is commanded to a filter (rate) which is not assigned (N/A), the
error 2 message will be returned.

B.2.4.2.3 Select Demodulator Rate Variable

Note: This command is only applicable for the variable rate option.

Command:

Response:

>add/SDRV_nnn_mmmm.m”cr””lf”]

Status Only: (See DR command.)

Where:

nnn = 1/2, 3/4, 7/8, or BP12 (Coder rate).
mmmm.m = 9.6 to 4080.0 (Data rate).