beautypg.com

Comtech EF Data SDM-650B User Manual

Page 318

background image

Trojan Interface

SDM-650B Satellite Modem

G–22

Rev. 5

G.6.4.1.3.5 Set Modulator Output Power Level

Command:

Response:

>add/MOP_snn.n”cr””lf”]


Status Only: Response:

>add/MOP_snn.n”cr””lf”]

Where:

For the 140 MHz modulator, snn.n = +20.0 to -45.0, in 0.5 dB increments.
For the 70 MHz modulator, snn.n = +20.0 to -30.0, in 0.5 dB increments.


Notes:

1. Power levels may be programmed for a maximum value specified by the

modulator power, offset with a range of 25 and 10 dB below the maximum value
for the 140 MHz modulator and the 70 MHz modulator, respectively.

2. See the “MPO_” command specification for more information.

G.6.4.1.3.6 Scrambler Enable

Command:

Response:

>add/SE_xxx”cr””lf”]


Status Only: Response:

>add/SE_xxx”cr””lf”]

Where: xxx = ON or OFF.

G.6.4.1.3.7 Differential Encoder Enable

Command:

Response:

>add/DENC_xxx”cr”lf”]


Status Only: Response:

>add/DENC_xxx”cr”lf”]

Where: xxx = ON or OFF.