B.2.8.8 Bit Error Rate Status

B.2.8.8.1 Raw BER

Command:

Response:

>add/RBER_nnnnE-4”cr””lf”]

Where:

nnnn = RBER.
nnnn = < 1.0 (lower limit).

Example: Request raw BER from modem 123.

Command:

<123/RBER_”cr”

Response:

>123/RBER_152E-4”cr””lf”]

Where: RBER = 0.0152 errors/bit.


Note: “No Data” is returned if no carrier is detected (decoder not locked).

B.2.8.8.2 Corrected BER

Command:

Response:

>add/CBER_nE-m”cr””lf”]

Example: Request corrected BER from modem 19.

Command:

<19/CBER_”cr”

Response:

>19/CBER_2E-5”cr””lf”]

Where: CBER = 0.00002 errors/bit.


Notes:

1. Corrected BER limits are lower < 1E-8, upper > 1E-3.
2. “No Data” is returned if no carrier is detected (decoder not locked).