Remote Control Operation

SDM-650B Satellite Modem

B–22

Rev. 6

B.1.4.5 Common Equipment Status

The common equipment status command causes a block of data to be returned, which
indicates the status of the common equipment.

Command: Response:

>add/CES_”cr”
M&C_xxx”cr”

Monitor and Control Module (OK/FLT)

INT_xxx”cr”

Data Interface Module (OK/FLT)

TXC_xxx”cr”

Transmit Clock Loss (DS-1 only)

BAT_xxx”cr” Battery

(OK/FLT)

PS1_xxx”cr”

+5V Power Supply (OK/FLT)

PS2_xxx”cr”

+12V Power Supply (OK/FLT)

PS3_xxx”cr”

-12V Power Supply (OK/FLT)

MODE_xxxxxx”cr”

Mode (LOCAL or REMOTE)

SW_x.xxx”cr” Software

Version

SFLT_xx”cr””lf”]

Number of Stored Faults Logged (0 to 10)

B.1.4.6 Interface Receive Side Status

Command:

Response:

>add/IRXS_”cr”
OVFL_xxx”cr”

Buffer Overflow (OK/FLT)

UNFL_xxx”cr”

Buffer Underflow (OK/FLT)

SFLT_xx”cr””lf”]

Number of Stored Faults Logged (0 to 10)


Note: This command is only valid when Buffer Control is enabled. See the “BUFF_”
command definition.