B.1.4.5 Common Equipment Status
The common equipment status command causes a block of data to be returned, which
indicates the status of the common equipment.
Command:
>add/CES_”cr”
M&C_xxx”cr”
Monitor and Control Module (OK/FLT)
INT_xxx”cr”
Data Interface Module (OK/FLT)
TXC_xxx”cr”
Transmit Clock Loss (DS-1 only)
BAT_xxx”cr” Battery
(OK/FLT)
PS1_xxx”cr”
+5V Power Supply (OK/FLT)
PS2_xxx”cr”
+12V Power Supply (OK/FLT)
PS3_xxx”cr”
-12V Power Supply (OK/FLT)
MODE_xxxxxx”cr”
Mode (LOCAL or REMOTE)
SW_x.xxx”cr” Software
Version
SFLT_xx”cr””lf”]
Number of Stored Faults Logged (0 to 10)
B.1.4.6 Interface Receive Side Status
Command:
Response: >add/IRXS_”cr” Buffer Overflow (OK/FLT) UNFL_xxx”cr” Buffer Underflow (OK/FLT) SFLT_xx”cr””lf”] Number of Stored Faults Logged (0 to 10)
OVFL_xxx”cr”
Note: This command is only valid when Buffer Control is enabled. See the “BUFF_”
command definition.