beautypg.com

B.2.7.2.3 remote interface baseband loopback – Comtech EF Data SDM-650B User Manual

Page 230

background image

Remote Control Operation

SDM-650B Satellite Modem

B–54

Rev. 6

B.2.7.2.2 Remote Interface Substitution Pattern (Transmit 2047
Pattern)

Command:

Response:

>add/RISP_xxx”cr””lf”]


Status Only: Response:

>add/RISP_xxx”cr””lf”]

Where: xxx = ON or OFF (remote transmit 2047 pattern enable).

B.2.7.2.3 Remote Interface Baseband Loopback

Command:

Response:

>add/RBBL_xxx”cr””lf”]


Status Only: Response:

>add/RBBL_xxx”cr””lf”]

Where: xxx = ON or OFF (remote baseband loopback enable).

B.2.7.2.4 Remote Interface Read Error Status (Received 2047
Pattern)

This command returns 2047 BER from the remote AUPC modem. If data is not valid, the
message “No_Data” is returned instead of BER data.

Command:

Response:

>add/RRES_nE-e”cr””lf”]

Where:

n = 1 to 9 (error rate number).
e = 2 to 6 (exponent).

Example:

Command:

Response:

>add/RRES_2E-6”cr””lf”]