B.2.8.9 E

b

/N

0

The E

b

/N

0

status command causes the E

b

/N

0

ratio to be returned. E

b

/N

0

is returned in dB.

Command:

Response:

>add/EBN0_n.ndB”cr””lf”]

Example: Request E

b

/N

0

ratio from modem 2.

Command:

<2/EBN0_”cr”

Response:

>2/EBN0_6.2dB”cr””lf”]

Where: E

b

/N

0

= 6.2 dB.


Notes:

1. E

b

/N

0

limits are lower < 3.2 dB, upper > 9.7 dB.

2. “No Data” is returned if no carrier is detected (decoder not locked).

B.2.8.10 Modulator Rate

Command:

Response:

>add/MR_nnn_mmmm.m”cr””lf”]

Where:

nnn = 1/2, 3/4, 7/8, or BP12 (Coder rate).
mmmm.m = 9.6 to 4080.0 (Data rate).


Note: The parameters “nnn_mmmm.m” may be replaced by “N/A” to indicate “no
assignment.”

B.2.8.11 Demodulator Rate

Command:

Response:

>add/DR_nnn_mmmm.m”cr””lf”]

Where:

nnn = 1/2, 3/4, 7/8, or BP12 (Decoder rate).
mmmm.m = 9.6 to 4080.0 (Data rate).


Note: The parameters “nnn_mmmm.m” may be replaced by “N/A” to indicate “no
assignment.”