beautypg.com

B.1.4.13 stored faults – Comtech EF Data SDM-650B User Manual

Page 202

background image

Remote Control Operation

SDM-650B Satellite Modem

B–26

Rev. 6

B.1.4.13 Stored Faults

Information on stored faults is returned when requested. If no stored fault exists for a
given fault number, the words “NO FAULT” will be returned instead of the normal
time/date status information.

The following symbols are commonly used to define the stored faults status commands:

• “#”

Fault number (0 to 9), “0” is the first fault stored.

• hh

Hours in 24-hr. format.

• mm Minutes.
• ss

Seconds.

• MM Month.
• DD Day.
• YY Year.

B.1.4.13.1 Modulator Stored Faults

Command:

Response:

>add/MSF_# hh:mm:ss MM/DD/YY”cr”
MOD_xxx”cr”

Module missing or will not program (OK/FLT)

AGC_xxx”cr”

AGC leveled (OK/FLT)

SYN_xxx”cr”

Carrier synthesizer (OK/FLT)

BCLK_xxx”cr”

Bit clock (OK/FLT)

TCLK_xxx”cr”

Transmit clock (OK/FLT)

ICH_xxx”cr”

I Channel (OK/FLT)

QCH_xxx”cr””lf”]

Q Channel (OK/FLT)

B.1.4.13.2 Demodulator Stored Faults

Command:

Response:

>add/DSF_# hh:mm:ss MM/DD/YY”cr”
DMD_xxx”cr”

Demod Module (OK/FLT)

CD_xxx”cr”

Carrier Detect (OK/FLT)

SYN_xxx”cr”

Synthesizer Lock (OK/FLT)

DSCR_xxx”cr”

Descrambler (OK/FLT)

ICH_xxx”cr”

I Channel (OK/FLT)

QCH_xxx”cr”

Q Channel (OK/FLT)

BCLK_xxx”cr”

Bit Clock (OK/FLT)

BERT_xxx”cr””lf”]

BER Threshold (OK/FLT)