B.2.8.16 stored faults – Comtech EF Data SDM-650B User Manual
Page 241

SDM-650B Satellite Modem
Remote Control Operation
Rev. 6
B–65
B.2.8.16 Stored Faults
Information on stored faults is returned when requested. If no stored fault exists for a
given fault number, the words “NO FAULT” will be returned instead of the normal
time/date status information.
The following symbols are commonly used to define the stored faults status commands:
• #
Fault number (0 to 9), “0” is the first fault stored.
• hh
Hours in 24-hr. format.
• mm Minutes.
• ss
Seconds.
• MM Month.
• DD Day.
• YY Year.
B.2.8.16.1 Modulator Stored Faults
Command:
Response: >add/MSF_# hh:mm:ss MM/DD/YY”cr” Module missing or will not program (OK/FLT) AGC_xxx”cr” AGC Leveled (OK/FLT) SYN_xxx”cr” Carrier Synthesizer (OK/FLT) BCLK_xxx”cr” Bit Clock (OK/FLT) TCLK_xxx”cr” Transmit Clock (OK/FLT) ICH_xxx”cr” I Channel (OK/FLT) QCH_xxx”cr””lf”] Q Channel (OK/FLT) B.2.8.16.2 Demodulator Stored Faults Command: Response: >add/DSF_# hh:mm:ss MM/DD/YY”cr” Demod Module (OK/FLT) CD_xxx”cr” Carrier Detect (OK/FLT) SYN_xxx”cr” Synthesizer Lock (OK/FLT) DSCR_xxx”cr” Descrambler (OK/FLT) ICH_xxx”cr” I Channel (OK/FLT) QCH_xxx”cr” Q Channel (OK/FLT) BCLK_xxx”cr” Bit Clock (OK/FLT) BERT_xxx”cr””lf”] BER Threshold (OK/FLT)
MOD_xxx”cr”
DMD_xxx”cr”