beautypg.com

B.2.8.12 receive signal level, B.2.8.13 current sweep value, B.2.8.14 interface buffer fill status – Comtech EF Data SDM-650B User Manual

Page 240: B.2.8.15 interface read error status

background image

Remote Control Operation

SDM-650B Satellite Modem

B–64

Rev. 6

B.2.8.12 Receive Signal Level

Command:

Response:

>add/RSL_-nn.ndBm”cr””lf”]

B.2.8.13 Current Sweep Value

This command returns the current sweep value and the decoder lock status.

Command:

Response:

>add/CSV_snnnnn”cr”

CD_xxx”cr””lf”]

Where:

s = + or - (sweep offset direction).
nnnnn = 0 to 25000.
xxx = OK or FLT (decoder lock status OK or FAULT).

B.2.8.14 Interface Buffer Fill Status

Command:

Response:

>add/IBFS_nn%”cr””lf”]

Where: nn = 1 to 99 (Relative to buffer depth).


Note:
Available with buffer support hardware only.

B.2.8.15 Interface Read Error Status

This command returns 2047 BER. If data is not valid, the message “No_Data” is returned
instead of BER data.

Command:

Response:

>add/IRES_nE-e”cr””lf”]

Where:

n = 1 to 9 (error rate number).
e = 2 to 6 (exponent).

Example:

Command:

Response:

>add/IRES_2E-6”cr””lf”]