SDM-650B Satellite Modem

Remote Control Operation

Rev. 6

B–29

Parameter 14 (p14): Demodulator rate currently programmed.

p14 = nnn_mmmm.m, where “nnn” is the code rate, and “mmmm.m” is the data rate in
kbit/s.

Parameter 15 (p15): Demodulator filter A assignment.

p15 = nnn_mmmm.m, where “nnn” is the code rate, and “mmmm.m” is the data rate in
kbit/s.

Parameter 16 (p16): Demodulator filter B assignment.

p16 = nnn_mmmm.m, where “nnn” is the code rate, and “mmmm.m” is the data rate in
kbit/s.

Parameter 17 (p17): Demodulator filter C assignment.

p17 = nnn_mmmm.m, where “nnn” is the code rate, and “mmmm.m” is the data rate in
kbit/s.

Parameter 18 (p18): Demodulator filter D assignment.

p18 = nnn_mmmm.m, where “nnn” is the code rate, and “mmmm.m” is the data rate in
kbit/s.

Parameter 19 (p19): Descrambler enable ON/OFF.

p19 = n, where “n” is “0” to indicate OFF, or “1” to indicate ON.

Parameter 20 (p20): Receive clock (Invert/Normal).

p20 = n, where “n” is “0” or “1” (“0” = NRM, “1” = INV).

Parameter 21 (p21): Baseband loopback ON/OFF.

p21 = n, where “n” is “0” to indicate OFF, or “1” to indicate ON.

Parameter 22 (p22): RF loopback ON/OFF.

p22 = n, where “n” is “0” to indicate OFF, or “1” to indicate ON.

Parameter 23 (p23): Not implemented.

p23 = “,”.

Parameter 24 (p24): BER threshold.

p24 = nnnn, where “nnnn” is the currently programmed BER threshold in the same
format as the single command “BERT_”.

Parameter 25 (p25): Sweep Reacquisition.

p25 = nnn, where “nnn” is the reacquisition parameter in seconds.

Parameter 26 (p26): IF loopback ON/OFF.

p26 = n, where “n” is “0” to indicate OFF, or “1” to indicate ON.

Parameter 27 (p27): MODEM REMOTE/LOCAL mode.

p27 = n, where “n” is “0” to indicate local, or “1” to indicate remote.

(See Note 1)

Parameter 28 (p28): Sweep center programmed.

p28 = snnnnn, where “s” is “+” or “-”, and “nnnnn” is the sweep center currently
programmed.

(See Note 1)

Parameter 29 (p29): Sweep width range.

p29 = nnnnn, where “nnnnn” is in the range of 0 to 50000 Hz.

(See Note 1)

Parameter 30 (p30): Sweep direction.

p30 = n, where “n” is “+” for positive or “-” for negative sweep direction.

(See Note 2)

Parameter 31 (p31): Buffer Clock.

p31 = n, where “n” is “0” to indicate transmit, “1” to indicate receive, or “2” to indicate
external.

(See Note 2)

Parameter 32 (p32): Interface Buffer Size.

p32 = nnnnn, where “nnnnn” is the buffer size in bits.


Notes:

1. Parameters 28, 29, and 30 are only returned when fast acquisition is enabled. See

the “FAM_” command definition. Commas are always returned.

2. Parameters 31 and 32 are only returned when Buffer Control is enabled. See the

“BUFF_” command definition. Commas are always returned.