beautypg.com

G.6.4.5.2 modem faults status (summary), G.6.4.5.3 modulator status, G.6.4.5.4 demodulator status – Comtech EF Data SDM-650B User Manual

Page 331

background image

SDM-650B Satellite Modem

Trojan Interface

Rev. 5

G–35

G.6.4.5.2 Modem Faults Status (Summary)

This command returns the current overall fault conditions of the modem.

Command:

Response:

>add/MFS_”cr”
DMD_xxx”cr”

Demodulator (FLT/OK)

MOD_xxx”cr”

Modulator (FLT/OK)

CEQ_xxx”cr””lf”]

Common Equipment (FLT/OK)

G.6.4.5.3 Modulator Status

The modulator status is returned as a block of data which indicates general status
information.

Command:

Response:

>add/MS_”cr”
RF_xxx”cr”

RF output (ON/OFF) actual status not config

MOD_xxx”cr”

Module missing or will not program (OK/FLT)

AGC_xxx”cr”

AGC leveled (OK/FLT)

SYN_xxx”cr”

Carrier synthesizer (OK/FLT)

BCLK_xxx”cr”

Bit clock (OK/FLT)

TCLK_xxx”cr”

Transmit clock (OK/FLT)

ICH_xxx”cr”

I-channel (OK/FLT)

QCH_xxx”cr”

Q-channel (OK/FLT)

SFLT_xx”cr””lf”]

Number of stored faults logged (0 to 10)

G.6.4.5.4 Demodulator Status

The demodulator status is returned as a block of data which provides general status
information.

Command:

Response:

>add/DS_”cr”
DMD_xxx”cr”

Demod module (OK/FLT)

CD_xxx”cr”

Carrier detect (OK/FLT)

SYN_xxx”cr”

Synthesizer lock (OK/FLT)

DSCR_xxx”cr”

descrambler (OK/FLT)

ICH_xxx”cr”

I-channel (OK/FLT)

QCH_xxx”cr”

Q-channel (OK/FLT)

BCLK_xxx”cr”

bit clock (OK/FLT)

BERT_xxx”cr”

BER threshold (OK/FLT)

RSL_-nn.ndBm”cr”

Receive Signal Level (level or No Data)

CSV_snnnnn”cr”

Current Sweep Value

SFLT_xx”cr””lf”]

Number of stored faults logged (0 to 10)