Avery Dennison Monarch 9864 Description of Commands User Manual
Page 93

10/07 Rev. AA
MANUAL EASY PLUG
Commands
All
devices
A = TTX 600 --TLX 604 – Eagle B = TTX 300 Offline -- Cobra Offline D = TTX 300 Online –TTX 207 -- Cobra Online – Da Capo
E = TTX 450/650/674/675/950/1050 – Puma/Puma plus/Lion/Lion plus/Tiger/Tiger XXL -- S45/65/95/105 -- TDI/STDI/XXTREME
G = TTX 350 – Ocelot – TTK – Texxtile H = 64-xx –Chess x –TT4 – DPM – PEM – ALX 92x – AP 4.4/5.4
93
0
Æ
1 mm, 1 Æ 2 mm, 2 Æ 3 mm bar code height, if parameter
PRINT PARAMETERS > Bar code multip.
is set to 1 (default).
•
TTX 207/300/480, Mustang 900/1000, Cobra and S 20/30:
Bar code height = h + 1
The h-value equals the bar code height (in milimeters):
0 Æ 1 mm, 1 Æ 2 mm, 2 Æ 3 mm etc.
•
0 = 5 mm, 1 = 10 mm, 2 = 15 mm,.... from 10 = actual height in mm
(e.g. 35 = 35 mm high). This height plus 1 is multiplied by the height zoom
factor in parameter
PRTP > BCHI
set at the printer.
•
All other printer groups:
0
Æ
5 mm, 1 Æ 10 mm bar code height; if h >= 10, the h-value equals the
bar code height in milimeters (e.g. 35 Æ 35 mm bar code heigth);
Precondition: parameter
PRTP > BCHI
is set to 1 (default).
Barcode-Höhe = (h + 1) * 5 *
PRTP > BCHI
(if h < 10)
Barcode-Höhe = (h + 1) *
PRTP > BCHI
(if h >= 10)
s = int
Bar code width factor:
Groups A, B, D, F
1 to
8
Groups E, G
1 to 16
Group H
1 to 30
opt.
v = +
Incrementation – offset is added to the text field.
= -
Decrementation – offset is subtracted from the text field.
opt.
o = int
Offset, which is added to (incremented) or subtracted from (decremented)
the TEXT depending on the prefix.
opt.
a = int
Number of labels with the same constant number (1 to 255).
TEXT =
Any alphanumerical text. The stipulations for the respective bar code must
be taken into consideration. Max. number of characters: 255.
The text field may alse be a variable data field. Precondition: the D-flag
must be set.
Syntax description: See chapter
(Only group H) The text field may contain an input field.
Syntax description: See chapter
#G =
The command #YB must be closed with #G.
Examples
#YB2/0M/2/2///1234567890123#G
UPCA with plain-copy line,
normal print direction,
3 mm high (only valid with
a group H printer), width 2,
without offset.