T horizontal print position, Horizontal print position, The reference point #tx or #jx (see – Avery Dennison Monarch 9864 Description of Commands User Manual
Page 83

10/07 Rev. AA
MANUAL EASY PLUG
Commands
All
devices
A = TTX 600 --TLX 604 – Eagle B = TTX 300 Offline -- Cobra Offline D = TTX 300 Online –TTX 207 -- Cobra Online – Da Capo
E = TTX 450/650/674/675/950/1050 – Puma/Puma plus/Lion/Lion plus/Tiger/Tiger XXL -- S45/65/95/105 -- TDI/STDI/XXTREME
G = TTX 350 – Ocelot – TTK – Texxtile H = 64-xx –Chess x –TT4 – DPM – PEM – ALX 92x – AP 4.4/5.4
83
T
#T
Horizontal print position
Definition
Determines the horizontal print position with absolute value in mm.
The horizontal zero position is always the position of the first dot of the
printhead. Looked at in feed direction, this dot is placed at the right end of
the printhead. Exception: The zero position was shifted with the
command.
If the printhead is positioned at the inner limit (right end if viewed in feed
direction), the first dot has a distance of 1 mm to the material zero line. In
other words: Looked at in feed direction there is a 1 mm wide stripe at the
right end of the label, which stays unprinted.
Command must stand between #ER and #Q!
Syntax
#Tx
All
Groups
x = num
Horizontal print position in mm in relation to the zero position (see above)
Text outside of the defined label area is not printed.
Example
#T5
Text begins 5 mm from the left
#T20
Text begins 20 mm from the left
Tx
Feed
Zero point
DEMO TEXT
DEMO TEXT
Jx