beautypg.com

Rfw write typed data to rf tag, Write typed data to rf tag – Avery Dennison Monarch 9864 Description of Commands User Manual

Page 74

background image

10/07 Rev. AA

MANUAL EASY PLUG

Commands

All

devices

A = TTX 600 --TLX 604 – Eagle B = TTX 300 Offline -- Cobra Offline D = TTX 300 Online –TTX 207 -- Cobra Online – Da Capo
E = TTX 450/650/674/675/950/1050 – Puma/Puma plus/Lion/Lion plus/Tiger/Tiger XXL -- S45/65/95/105 -- TDI/STDI/XXTREME
G = TTX 350 – Ocelot – TTK – Texxtile H = 64-xx –Chess x –TT4 – DPM – PEM – ALX 92x – AP 4.4/5.4

74

#RFW Write typed data to RF tag

Definition

This command writes data of well-defined type onto a RFID label.

Command must be placed between #ER and #Q!

Syntax

#RFWt/abfs/r/vo/a/n/DATA#G

Group

H

t = int

data type
0 = BLOCK
1 = UID
2 = EPC

opt.

a = I

data assumed in DATA as ASCII(default)
Each byte in DATA is written to chip in identical form. There is no
interpretation. This is especially designed for printable byte codes as ASCII
characters.

= B

data assumed in DATA in hex representation:
Two consecutive bytes in DATA are interpreted as hexadecimal description
for a byte code. This byte code is written on chip. This is especially
designed for NON printable byte codes.

opt.

b = L

Least significant byte of block first (default) :
Bytes of DATA are written on transponder beginning with the LSB first.

= M

Most significant byte of block first:
Bytes of DATA are written on transponder beginning with the MSB first.

opt.

f = P

locking option (write protect), default: don’t’ lock (NOT YET
IMPLEMENTED)

opt.

s = int

Address of start block. Default setting: 0

opt.

r = int

Number of read/write retries. Default defined by parameter “Nr of CMD
retries”.

opt.

v = +

Incrementation – offset is added to the text field. (NOT YET
IMPLEMENTED)

= -

Decrementation – offset is subtracted from the text field.

opt.

o = int

Offset, which is added to (incremented) or subtracted from (decremented)
the TEXT depending on the prefix. (NOT YET IMPLENTED)

opt.

a = int

Number of labels with the same constant number (1 to 255). (NOT YET
IMPLEMENTED)

n = int

Number of characters in DATA

DATA

data to be written

Example

#RFW2/B////24/01203D2A916E8
B8719BAE03C

12 bytes as an EPC 96 in hex
representation