#RFW Write typed data to RF tag
Definition
This command writes data of well-defined type onto a RFID label.
Command must be placed between #ER and #Q!
Syntax
#RFWt/abfs/r/vo/a/n/DATA#G
Group
H
t = int
data type
0 = BLOCK
1 = UID
2 = EPC
opt.
a = I
data assumed in DATA as ASCII(default)
Each byte in DATA is written to chip in identical form. There is no
interpretation. This is especially designed for printable byte codes as ASCII
characters.
= B
data assumed in DATA in hex representation:
Two consecutive bytes in DATA are interpreted as hexadecimal description
for a byte code. This byte code is written on chip. This is especially
designed for NON printable byte codes.
opt.
b = L
Least significant byte of block first (default) :
Bytes of DATA are written on transponder beginning with the LSB first.
= M
Most significant byte of block first:
Bytes of DATA are written on transponder beginning with the MSB first.
opt.
f = P
locking option (write protect), default: don’t’ lock (NOT YET
IMPLEMENTED)
opt.
s = int
Address of start block. Default setting: 0
opt.
r = int
Number of read/write retries. Default defined by parameter “Nr of CMD
retries”.
opt.
v = +
Incrementation – offset is added to the text field. (NOT YET
IMPLEMENTED)
= -
Decrementation – offset is subtracted from the text field.
opt.
o = int
Offset, which is added to (incremented) or subtracted from (decremented)
the TEXT depending on the prefix. (NOT YET IMPLENTED)
opt.
a = int
Number of labels with the same constant number (1 to 255). (NOT YET
IMPLEMENTED)
n = int
Number of characters in DATA
DATA
data to be written
Example
#RFW2/B////24/01203D2A916E8
B8719BAE03C
12 bytes as an EPC 96 in hex
representation